首页 | 本学科首页   官方微博 | 高级检索  
     

近红外光谱技术对猪肉注水、注胶的快速检测
引用本文:孟一,张玉华,许丽丹,陈东杰,张应龙,张咏梅.近红外光谱技术对猪肉注水、注胶的快速检测[J].食品科学,2014,35(8):299-303.
作者姓名:孟一  张玉华  许丽丹  陈东杰  张应龙  张咏梅
作者单位:1.山东商业职业技术学院 山东省农产品贮运保鲜技术重点实验室,山东 济南 250103;; 2.国家农产品现代物流工程技术研究中心,山东 济南 250103
基金项目:济南市高校院所自主创新计划项目(201202060);“十二五”国家科技支撑计划项目(2013BAD19B02);山东省科技发展计划项目(2012GNC11009)
摘    要:采用近红外光谱(near infrared spectroscopy,NIR)结合主成分分析(principal component analysis,PCA) 和判别分析法建立了注水肉、注胶肉和正常肉的定性判别模型。注水肉中注水量的多少对判别准确率产生影响, 当注水量为1.25%~20%时,3 种肉的总体判别准确率为94.23%;当注水量为3.75%~20%时,判别准确率提高至 96.96%。模型对所有预测集样品的总体判别准确率为94.92%。表明NIR结合PCA法、判别分析法判别注水肉、注胶 肉和正常肉具有可行性。采用偏最小二乘法(partial least squares,PLS)结合PCA分别建立了注水量和注胶量的定 量分析模型,经验证,两种模型对预测集样品的预测均方差分别为4.01%和3.87%,预测值与实测值间的相关系数 (r)分别为0.904 2和0.912 8。表明两种模型的预测性能良好。

关 键 词:近红外光谱  注水肉  注胶肉  判别分析  偏最小二乘法  

Rapid Detection of Meat Injected with Water or Gum by Near Infrared Spectroscopy
MENG Yi,ZHANG Yu-hua,XU Li-dan,CHEN Dong-jie,ZHANG Ying-long,ZHANG Yong-mei.Rapid Detection of Meat Injected with Water or Gum by Near Infrared Spectroscopy[J].Food Science,2014,35(8):299-303.
Authors:MENG Yi  ZHANG Yu-hua  XU Li-dan  CHEN Dong-jie  ZHANG Ying-long  ZHANG Yong-mei
Affiliation:1. Shandong Key Laboratory of Storage and Transportation Technology of Agricultural Products, Shandong Institute of Commerce and Technology,; Jinan 250103, China; 2. National Engineering Research Center for Agricultural Products Logistics, Jinan 250103, China
Abstract:A qualitative model for discriminating water-injected meat, gum-injected meat from normal meat was established by
near infrared spectroscopy (NIR) combined with principal component analysis (PCA) and discriminant analysis. The amount of
water injection had an impact on the discrimination accuracy. The overall discrimination accuracy between normal and adulterated
meat was 94.23% when the amount of water injection was 1.25%–20%, and was increased to 96.96% upon water injection at levels
between 3.75% and 20%. The overall discrimination accuracy for all samples in the prediction set was 94.92%. These results show
that NIR combined with PCA and discriminant analysis is feasible to discriminate water-injected meat, gum-injected meat from
normal meat. Quantitative analysis models of water injection and gum injection were established using partial least squares (PLS)
combined with PCA. On the basis of verification, the root mean square errors of prediction (RMSEP) from the two models were
4.01% and 3.87%, respectively, and the correlation coefficients (r) between the predicted values and the actual values were 0.904 2
and 0.912 8, respectively. Therefore, both models have good prediction performance.
Keywords:near infrared spectroscopy (NIR)  water-injected meat  gum-injected meat  discriminant analysis  partial least squares  
本文献已被 CNKI 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号