Intraoperative monitoring of the function of the peroneal nerve in knee joint operations |
| |
Authors: | H Wissel W Nebelung F Awiszus |
| |
Affiliation: | Otto-von-Guericke Universit?t Magdeburg, Medizinische Fakult?t, Orthop?dische Universit?tsklinik. heiko.wissel@medizin.uni-magdeburg.de |
| |
Abstract: | ![]() Operations on the knee are known to be associated with postoperative neurological complications. There is no consensus opinion on the causes of these complications. The aim of the present study was to develop a method for the intraoperative monitoring of the function of the common peroneal nerve. This was done as to identify intraoperative factors that might be responsible for reversible and irreversible neurological deficits. Computer-aided neuromonitoring is based on online digitizing of the surface EMG of the anterior tibial muscle. An algorithm continuously modifies the amplitude to determine the motor threshold. The method described has been used in 18 patients undergoing high tibial osteotomy. In 10 of the 18 patients, the nerve is rendered completely non-excitable after an average tourniquet application time of 59 min. This non-excitability was reversed on release of the tourniquet. In the remaining 8 patients, excitability was maintained throughout the ischaemic period, which did not exceed 60 minutes in any of the cases. Our method enables accurate quantification of the neural function throughout the entire operation, and convincingly documents the influence of ischaemia on peripheral nerve block. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|