首页 | 本学科首页   官方微博 | 高级检索  
     

两跨连续GFRP-混凝土空心组合板受力性能试验研究
引用本文:黄辉,王文炜,戴建国.两跨连续GFRP-混凝土空心组合板受力性能试验研究[J].建筑结构学报,2015,36(10):59-65.
作者姓名:黄辉  王文炜  戴建国
作者单位:1. 东南大学 交通学院, 江苏南京 210096; 2. 香港理工大学 土木与环境工程系, 香港 999077
基金项目:国家自然科学基金项目(51078079,51578135)。
摘    要:为研究两跨连续GFRP-混凝土空心组合板的受力性能,进行了2个连续组合板试件的静力加载试验。组合板分别采用环氧树脂胶及栓钉与下部工字钢支座进行连接。试验结果表明,试件最终破坏形态均为跨中截面处受压区混凝土压碎后,下部GFRP型材下翼缘断裂或侧壁屈曲破坏。采用环氧树脂胶连接的试件,边支座可以视为简支支座;采用栓钉连接的试件,边支座可以视为固定支座。随着负弯矩区混凝土的开裂及受拉钢筋的屈服,组合板均出现了明显的内力重分布现象。基于截面分析方法和等效刚度,提出了连续组合板受力全过程计算方法。计算结果表明,组合板的支座反力和截面弯矩试验值与理论值吻合较好,提出的方法可以有效地用于组合板的全过程受力分析。

关 键 词:静力试验    连接方式    内力重分布    受力性能  连续GFRP-混凝土空心组合板  

Experimental study on structural performance of two-span continuous GFRP-concrete composite hollow slabs
HUANG Hui,WANG Wenwei,DAI Jianguo.Experimental study on structural performance of two-span continuous GFRP-concrete composite hollow slabs[J].Journal of Building Structures,2015,36(10):59-65.
Authors:HUANG Hui  WANG Wenwei  DAI Jianguo
Affiliation:1. School of Transportation, Southeast University, Nanjing 210096, China;; 2. Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China
Abstract:Static tests on two-span continuous GFRP-concrete composite hollow slabs supported on steel girders were conducted to investigate their structural performance. The connections between the steel girders and the GFRP-concrete composite slabs were realized by adhesive connection and mechanical connection, respectively. The observed failure modes for the two specimens were both concrete crushing followed by the bottom flange rupture or side wall buckling of GFRP profiles at the mid-span section. Two external supports for the specimen connected with adhesive connection can be considered as the simply support constraints. However, the fixed support constraints can be approximated for the specimen mechanically connected with shear studs. During the tests, the internal force redistributions were observed after concrete cracking and tensile steel reinforcement yielding at the negative moment regions. Based on the sectional analysis method and sectional equivalent stiffness, a full-process calculation method for the two-span continuous GFRP-concrete composite hollow slabs was proposed. The analytical results show that there is a good agreement between the tested and calculated values of the support reaction and the sectional bending moment, respectively. The proposed method can predict the full-process mechanics of the continuous composite slabs effectively.
Keywords:internal force redistribution  mechanical performance  static test  connection form  continuous GFRP-concrete composite hollow slab  
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏