产品的响应与消除次冲击
引用本文:于治会.产品的响应与消除次冲击[J].电气开关,2001(2):17-21,32.
作者姓名:于治会
作者单位:沈阳新乐精密机器公司,辽宁,沈阳,110034
摘    要:本文阐述了在跌落冲击试验时主冲击与次冲击的特点,计算了产品模型对一个单次冲击循环的响应,并分析了产品损坏的原因,当产品进行精密冲击试验时,消除次冲击是很有必要的。

关 键 词:次冲击  系统响应  产品损坏  消除次冲击  产品模型  平板橡胶减振器  JP-1-0.45型  冲击试验
文章编号:1004-289X(2001)02-0017-05

The Necessary of Eliminating Secondary Shocks Based on the Damage of Product System
YU zhi-hui.The Necessary of Eliminating Secondary Shocks Based on the Damage of Product System[J].Electric Switchgear,2001(2):17-21,32.
Authors:YU zhi-hui
Abstract:This paper described the characteristics of major shock and secondary shocks in drop-test.It calculated the product system response on a shock course and analysed the reason of product damaging.When the product is carried out for accurate shock teting,it is very necessary to eliminate the secondry shocks.
Keywords:major shock  secondary shock  system response  product damage  eliminating secondary shock    