150MW空冷汽轮发电机温度异常分析
引用本文:高阳,于涛. 150MW空冷汽轮发电机温度异常分析[J]. 防爆电机, 2011, 46(4): 10-12
作者姓名:高阳  于涛
作者单位:1. 吉林省电力勘测设计院,吉林,长春,130022
2. 哈尔滨大电机研究所,黑龙江,哈尔滨,150040
摘    要:首先对出现温度异常的机组进行了通风试验,测试了其运行时的实际风量;其次利用网络法计算了发电机总风量及其风量分配,并在此基础上,利用有限元法对其定子温度场进行了计算;最后分析了150MW空冷汽轮发电机在运行中出现定子铁心温度和定子线圈温度异常的原因.

关 键 词:空冷汽轮发电机  温度异常  定子温度场

Analysis on Abnormal Temperature of 150MW Air-Cooled Turbo-Generator
Gao Yang,Yu Tao. Analysis on Abnormal Temperature of 150MW Air-Cooled Turbo-Generator[J]. Explosion-proof Electric Machine, 2011, 46(4): 10-12
Authors:Gao Yang  Yu Tao
Affiliation:Gao Yang and Yu Tao
Abstract:Firstly,the ventilation test was performed to measure actual air flow of the unit at operation with abnormal temperature.Secondly,the total air flow of the generator and its distribution were calculated by network method.Based on it,the stator temperature field of the generator was calculated by FEM.Lastly,the reasons of abnormal temperature occurred in stator core and stator coils of 150MW air-cooled turbo-generator at operation were analyzed.
Keywords:Air-cooled turbo-generator  abnormal temperature  stator temperature field  