首页 | 本学科首页   官方微博 | 高级检索  
     

制冷剂泄漏对家用空调器压缩机的影响
引用本文:方祥建,程睿,邵英,吴丽花. 制冷剂泄漏对家用空调器压缩机的影响[J]. 制冷与空调(北京), 2013, 0(3): 41-45
作者姓名:方祥建  程睿  邵英  吴丽花
作者单位:珠海格力电器股份有限公司
摘    要:制冷剂泄漏不仅会导致家用空调器制冷、制热效率下降,而且会严重影响甚至损坏压缩机。本文通过试验分析空调器制冷剂泄漏对压缩机的损害机制,并在家用空调器和压缩机的设计方面采取一系列应对措施,增强空调器和压缩机在发生制冷剂泄漏时的自我保护能力,大幅降低家用空调器压缩机的售后故障率。

关 键 词:家用空调器  制冷剂泄漏  压缩机

Influence of refrigerant leakage on compressor of household air conditioner
Fang Xiangjian Cheng Rui Shao Ying Wu Lihua. Influence of refrigerant leakage on compressor of household air conditioner[J]. Refrigeration and Air-conditioning, 2013, 0(3): 41-45
Authors:Fang Xiangjian Cheng Rui Shao Ying Wu Lihua
Affiliation:Fang Xiangjian Cheng Rui Shao Ying Wu Lihua (Gree Electric Appliances, Inc. of Zhuhai)
Abstract:Refrigerant leakage will not only reduce the efficiency of cooling or heating but also damage the compressor. The impact of refrigerant leakage on compressor is analyzed based on a series of tests. The corresponding solutions on design of air conditioner and compressor are researched so as to enhance the self-protection ability of the unit when refrigerant leakage occurs. After-sales failure rate of the air conditioner's compressor is reduced.
Keywords:household air conditioner  refrigerant leakage  compressor