首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of dimethindene in human tears by high-performance liquid chromatography
Authors:DF Chollet  P Bibas  G Anderegg  V Arnera  R Lanz
Affiliation:Covance Central Laboratory Services SA, Medical Affairs, Meyrin/Geneva, Switzerland.
Abstract:
A high-performance liquid chromatographic method is described for the determination of dimethindene in human tears. The tear samples were diluted in a 0.01 M hydrochloric acid-n-propanol mixture to prevent the irreversible adsorption of dimethindene. The diluted samples were directly injected into the chromatographic system to avoid sample pretreatment. The validation data demonstrate that the method is specific, precise and accurate within the calibration range of 12 to 1000 ng/ml dimethindene free base.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏