首页 | 本学科首页   官方微博 | 高级检索  
     

电站锅炉容克式空气预热器漏风治理
引用本文:王正杰.电站锅炉容克式空气预热器漏风治理[J].华中电力,2010,23(3):51-54.
作者姓名:王正杰
作者单位:大唐洛阳热电厂,河南,洛阳471039
摘    要:大唐洛阳热电厂两台300MW机组5、6号锅炉,每台炉安装2台型号为LAP10320/883的空气预热器,5号炉空预器漏风率已由机组投运初期的8%增加到24.9%左右。5号机组的负荷在290MW时引风机出力已达到最大值,使机组不能满负荷运行,空预器漏风已影响到了机组出力和经济运行。为了使空预器运行满足锅炉满负荷运行要求,达到节能降耗目的,对5号炉空气预热器进行了密封改造和漏风治理。

关 键 词:空预器  漏风  治理  节能降耗

The Air Leakage Control of Utility Boiler Ljungstrom Trisector Air Preheater
WANG Zheng-jie.The Air Leakage Control of Utility Boiler Ljungstrom Trisector Air Preheater[J].Central China Electric Power,2010,23(3):51-54.
Authors:WANG Zheng-jie
Affiliation:Luoyang Thermal Power Plant, Luoyang 471039,China
Abstract:In Datang Luoyang Thermal Power Plant, there are two boilers of 300MW machine set, No.5 and No.6. Two air preheaters, Model LAP10320/883, are installed on each of them. When the machine set was just put into use, the rate of air lackage of No.5 was 8%. Now it increases to 24.9% or so. When the load of No.5 boiler is 290MW, its IDF(induced draft fan) has already reached the maximum. As a result, the machine set can't run at full capacity. The leakage of air preheaters has affected the use of the machine set and made the operation uneconomic. In order to make the operation of air preheaters meet the operational requirements that the boiler should run at full capacity, to the air preheaters of No.5 boiler, we carried out sealing rehabilitation and air leakage control, so that we can save energy and lower energy consumption.
Keywords:air preheater  air leakage  control  energy saving and consumption reduction
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《华中电力》浏览原始摘要信息
点击此处可从《华中电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏