首页 | 本学科首页   官方微博 | 高级检索  
     


Response of a thermoacoustic refrigerator to the variation of the driving frequency and loading
Authors:Fathi Jebali  Jean Valentin Lubiez  Maurice-Xavier Franois
Affiliation:LIMSI-CNRS, BP 133, 91403, Orsay Cedex, France
Abstract:The performance of a thermoacoustic refrigerator subjected to variable loading was analyzed experimentally and the data were compared with those obtained using a computational model. The computational model relies on one-dimensional cross-section-averaged equations discretized using the network analogy. The thermoacoustic refrigerator was modeled by dividing it into 1 mm long slices in the direction of the acoustic axis. The hot heat exchanger of the thermoacoustic refrigerator was maintained at ambient temperature and the temperature of the cold heat exchanger was varied to achieve temperature differences of ΔT=0, 5 and 10 K along the stack. The cooling load was measured and calculated for these temperature differences while varying the driving frequency between 30 and 65 Hz. The contribution of the progressive and stationary waves and the losses on the thermoacoustic heat flow was computed and discussed.
Keywords:Refrigeration  Thermoacoustics  Modelling  Experimental  Heat transferRefrigé  ration  Thermoacoustique  Modé  lisation  Expé  rimentation  Transfert de chaleur
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号