首页 | 本学科首页   官方微博 | 高级检索  
     

心电信号采集电路的设计
引用本文:师彦荣,胡进峰. 心电信号采集电路的设计[J]. 电子世界, 2012, 0(18): 109-110
作者姓名:师彦荣  胡进峰
作者单位:[1]电子科技大学电子工程学院 [2]四川理工学院自电学院
摘    要:
心电信号是人类最早研究生物电信号之一,并较早的应用到医学临床。本文根据心电信号的低频率、低幅值和人体高阻抗等特点,设计了一个用于心电信号采集的电路。该电路主要由传感器电极、右腿驱动电路、前置放大电路、低通滤波电路、高通滤波电路、50Hz陷波电路以及后置放大电路组成。该电路较好的降低了共模信号的干扰以及工频干扰,可以采集到较好的心电信号。

关 键 词:心电信号  右腿驱动电路  滤波电路  放大电路

Design of the detection circuit for electrocardio-signal
Affiliation:( 1.school of electronic engineering, University of Electronic Science and Technology of China Chengdu 610500; 2.Automation and electronic information institute, Sichuan university of science&engineering Zigong 643000 )
Abstract:
The ECG is one of the bioelectrical signals that are researched and used in clinical medicine early.A detection circuit for electrocardio-signal was designed on the basis of the characteristics of electrocardio-signal that is low frequency, small amplitude and high resistance of body.It included electrodes, driven-fight-leg circuit, Pre-amplifier circuit, Low pass filter circuit, High pass filter circuit, 50Hz rejector circuit and Post amplifier circuit.It can be extracted from human body satisfactorily, because of dislodging the common-mode signal and power frequency.
Keywords:electrocardio-signal  driven-right-legcircuit  filter circuit  amplifier circuit