火焰原子吸收法连续测定铜镉渣中的铜镉铅锌
引用本文:王永青.火焰原子吸收法连续测定铜镉渣中的铜镉铅锌[J].湖南有色金属,2010,26(6):61-63.
作者姓名:王永青
作者单位:湖南省有色地质勘查局二四五队,湖南吉首416007
摘    要:一种利用火焰原子吸收法快速测定铜镉渣中铜、镉、铅、锌的方法。试样经王水消解后,在试验条件下进行测定,加标回收率为97.9%~100.8%,相对标准偏差为1.59%~14.29%,具有较高的精密度和准确度。该法适用于铜镉渣中Cu、Cd、Pb、Zn含量大于0.1%试样的测定。

关 键 词:火焰原子吸收  铜镉渣        

Continuous Determination of Copper Cadmium Lead and Zinc in Copper and Cadmium Sediment by FAAS
WANG Yong-qing.Continuous Determination of Copper Cadmium Lead and Zinc in Copper and Cadmium Sediment by FAAS[J].Hunan Nonferrous Metals,2010,26(6):61-63.
Authors:WANG Yong-qing
Affiliation:WANG Yong-qing(Bringde 245 of Hunan Bureau of Nonferrous Metais Geology Inverstigation,Jishou 416007,China)
Abstract:This is a method to continuously determine copper,cadmium,lead and zinc concentration in copper and cadmium sediment by FAAS.The sample is digested with acid mixture of HCl-HNO3.Under the determination condition,the recoveries are in the range 97.9%~100.8% and the RSDS of the method are found to be in the range1.59%~14.29%.This method is sensitive when the concentration of Cu,Cd,Pb and Zn is higher than 0.1% respectively.
Keywords:FAAS  copper and cadmium sediment  Cu  Cd  Pb  Zn