首页 | 本学科首页   官方微博 | 高级检索  
     

双加压硝酸装置中低压反应水冷凝器泄漏及改进
引用本文:王全文.双加压硝酸装置中低压反应水冷凝器泄漏及改进[J].煤化工,2013(6):37-39.
作者姓名:王全文
作者单位:万华化学集团股份有限公司,山东烟台264006
摘    要:介绍了双加压硝酸装置中低压反应水冷凝器的作用和特性,通过对低压反应水冷凝器运行状况和泄漏现象分析,认为该设备发生腐蚀泄漏的主要原因是氯离子聚集的应力腐蚀,并提出了改进的建议:采用内孔焊接工艺、改变换热器结构、控制相关的工艺指标等。

关 键 词:双加压硝酸装置  低压反应水冷凝器  腐蚀  泄漏

Cause of the Leakage of the Low-pressure Reaction Water Condenser in the Dual-pressure Nitric Acid Plant
Wang Quanwen.Cause of the Leakage of the Low-pressure Reaction Water Condenser in the Dual-pressure Nitric Acid Plant[J].Coal Chemical Industry,2013(6):37-39.
Authors:Wang Quanwen
Affiliation:Wang Quanwen (Wanhua Chemical Group Co., Ltd., Yantai Shandong 264006, China)
Abstract:The function and features of the low-pressure reaction water condenser in a dual-pressure nitric acid plant was introduced. The analysis on the operation conditions and leakage of the condenser revealed that stress corrosion due to the gathering of the chloride ions was the key cause of the leakage of the condenser. Suggestions for correcting this problem were proposed.
Keywords:nitric acid plant  low-pressure reaction water condenser  corrosion  leakage