首页 | 本学科首页   官方微博 | 高级检索  
     

替代汞三相点的研究和新温标展望
引用本文:张金涛,梁宇,冯晓娟.替代汞三相点的研究和新温标展望[J].计量学报,2022,43(2):145-150.
作者姓名:张金涛  梁宇  冯晓娟
作者单位:中国计量科学研究院,北京 100029
基金项目:国家自然科学基金(51976206);
摘    要:从国际温标ITS-90的定义固定点中替代汞三相点,是全球禁止汞的商业交易公约实施的必然结果,也是国际温度计量领域的一个研究热点.要达到替代的目标,候选替代物三相点温坪的计量性能必须达到汞三相点的水平,替代物三相点的复现装置成本可接受、复现技术不复杂;汞三相点被替代后,必然引起温标结构的改变.针对上述问题,对国际温度计量...

关 键 词:计量学  90国际温标  汞三相点  氙三相点  六氟化硫三相点  二氧化碳三相点  温标修订
收稿时间:2021-11-23

Prospect for Replacement of the Mercury Triple Point and a New Temperature Scale
ZHANG Jin-tao,LIANG Yu,FENG Xiao-juan.Prospect for Replacement of the Mercury Triple Point and a New Temperature Scale[J].Acta Metrologica Sinica,2022,43(2):145-150.
Authors:ZHANG Jin-tao  LIANG Yu  FENG Xiao-juan
Affiliation:National Institute of Metrology, Beijing 100029, China
Abstract:The replacement of the mercury triple point from the set of the defining points consituting the International Temperature Scale ITS-90 is indispensable in correspondence to the prohibition action of mercury from commercial trade. The research with the replacement of the mercury triple point is a hot point in the international thermometry community. Finishing such an objective, the thermometric properties of candidates are required to agree with the levels of the triple point of mercury. In addition, the cost and impact to most of users are acceptable with the replacement, the thermometric technology with the new fixed point(s) is as convenience as the old one. The change for the temperature scale with the replacement has to be addressed for every possibility. The researches on replacing mercury triple point in the international thermometry community are reviewed, and the prospect and suggestions on how to revise the new temperature scale are put forward.
Keywords:metrology  ITS-90  mercury triple point  xenon triple point  sulfur hexafluoride triple point  carbon oxide triple point  temperature scale revision  
本文献已被 万方数据 等数据库收录!
点击此处可从《计量学报》浏览原始摘要信息
点击此处可从《计量学报》下载全文