首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of fatigue damage in reinforced concrete slab by acoustic emission
Authors:S. Yuyama   Z. -W. Li   M. Yoshizawa   T. Tomokiyo  T. Uomoto
Abstract:
The applicability of acoustic emission (AE) technique for evaluation of fatigue damage in reinforced concrete (RC) slabs under cyclic loadings in both laboratory and as a structure in service is studied. The fundamental test performed in laboratory shows that the cracking process can be practically monitored by the measurement of AE signals. Analysis of the relationship between loading phase and AE activity indicates that the final stages of the fracture process can be evaluated by detecting AE signals generated near the minimum loading phase. Comparison of the results from the structure and that from the laboratory specimen demonstrates that AE energy can be an effective parameter for the evaluation of fatigue damage in RC slabs in service.
Keywords:Acoustic emission   Non-destructive evaluation   Fatigue loading   Reinforced concrete slab
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏