首页 | 本学科首页   官方微博 | 高级检索  
     


Characteristics of modified CT injector for JFT-2M
Authors:N. Fukumoto   H. Ogawa   M. Nagata   T. Uyama   T. Shibata   Y. Kashiwa   Y. Kusama  JFT-M Group
Affiliation:

aHimeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201, Japan

bJapan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193, Japan

Abstract:The HIT-CTI mark II compact toroid (CT) injector employed for the JFT-2M tokamak facility at the Japan Atomic Energy Research Institute (JAERI) has been upgraded to improve injection performance. The nozzle of the mark III injector now has a linear tube in place of the original focus cone to avoid rapid focus and deceleration, and the tapered outer electrode has been replaced with more gentle taper in the compression section in order to facilitate gradual compression. The dependence of CT velocity and electron density on poloidal bias flux and trigger time of CT acceleration have been investigated in the operable range of 70–230 km/s average CT velocity and electron density of 0.1–1.0 × 1022 m−3 at an accelerator bank voltage of 25 kV. The operation window is broader than that of the mark II injector. Emission of a CT plasmoid from the injector, and transport to the flux conserver as a high-density spheromak magnetic structure have also been confirmed.
Keywords:Compact toroid   Tokamak plasmas   H-mode plasmas