Characterisation and biological treatment of greywater. |
| |
Authors: | L Hernández Leal G Zeeman H Temmink C Buisman |
| |
Affiliation: | Wetsus, Centre for sustainable water technology, P.O. Box 1113 8900 CC, Leeuwarden, The Netherlands. lucia.hernandez@wetsus.nl |
| |
Abstract: | Characterisation of greywater was conducted in two different greywater streams in the Netherlands (Groningen and Sneek). The concentrations of macropollutants and nutrients measured were very different in both streams; in particular the COD was 425 mg/L in Groningen's water whereas in Sneek it was 1,583 mg/L. The aerobic treatment of greywater in a fed-batch reactor led to a 90% removal of COD at different organic loading rates. Anaerobically, the removal reached 40% COD removal on average, the possible reason being the high amount of surfactants present in the influent. |
| |
Keywords: | |
|
|