Determination of the energy savings and the optimum insulation thickness in the four different insulated exterior walls
Authors:Aynur Ucar  Figen Balo
Affiliation:aDepartment of Mechanical Engineering, Firat University, 23279 Elazığ, Turkey;bThe Ministry of Public Works and Settlement, Elazığ, Turkey
Abstract:The optimum insulation thickness of the external wall for four cities from four climate zones of Turkey, energy savings over a lifetime of 10 years and payback periods are calculated for the five different energy types and four different insulation materials applied externally on walls. Extruded polystyrene, expanded polystyrene, nil siding and rock wool as wall insulation material are selected. In this study, the net energy cost savings are calculated using the P1P2 method. The results show that energy cost savings vary between 4.2 $/m2 and 9.5 $/m2 depending on the city and insulation materials. The highest payback period value with 2.25 years in Mersin found by using natural gas as an energy source for heating, while the lowest value is reached by using LPG as an energy source in Bitlis.
Keywords:Energy cost savings  Life-cycle cost  Wall insulation