摘    要:将电网中不对称负荷产生的基波负序电能作为研究对象,以合理计量电能为研究目的 ,分析了不对称负荷产生的负序电能对电能计量的影响,针对现有有功电能计量方法存在的问题,提出了一种考虑不平衡责任的奖罚性电能计量新方法.采用功率分解的方法将PCC点处的负序有功功率分解为系统侧和用户侧产生的负序有功功率.基于IEEE Std.1459-2010功率理论提出了一种定量评估不平衡责任的新指标—负序视在功率,给出了不平衡责任的具体计算方法,并根据不平衡责任值设置了奖罚系数的参考值.设计具体的仿真算例,验证了在负序污染严重的电网中,采用所提奖罚性电能计量新方法更加公平、合理.

关 键 词:负序电能  电能计量  负序视在功率  不平衡责任  奖罚系数
收稿时间:2019/9/12 0:00:00
修稿时间:2019/9/12 0:00:00

A new method of rewarding and punishing electric energy metering considering unbalanced responsibility
Tuo Changjun,Tian Mingxing and.A new method of rewarding and punishing electric energy metering considering unbalanced responsibility[J].Electrical Measurement & Instrumentation,2021,58(11):150-156.
Authors:Tuo Changjun  Tian Mingxing and
Affiliation:School of Automation and Electrical Engineering,Lanzhou Jiaotong University,School of Automation and Electrical Engineering,Lanzhou Jiaotong University,School of Automation and Electrical Engineering, Lanzhou Jiaotong University
Abstract:Taking the negative sequence electric energy generated by asymmetric load in power grid as the research object, and aiming at the reasonable metering of electric energy, the influence of negative sequence power generated by asymmetric load on the metering of electric energy is first analyzed. In this paper, a new method of rewarding and punishing electric energy metering considering unbalanced responsibility is proposed for the existing problems of active power metering methods. Secondly, the power decomposition method is used to decompose the negative sequence active power at the PCC point into the utility side and the customer side negative sequence active power. Thirdly, based on IEEE Std.1459-2010 power theory, a new index of quantitative assessment of unbalanced responsibility, negative sequential apparent power, and a specific calculation method of unbalanced responsibility are given, and a reward and punishment coefficient reference value is set according to the unbalanced responsibility value. Finally, a concrete simulation example is designed to verify that the new method of rewarding and punishing electric energy metering is more fair and reasonable in the grid with serious negative sequence pollution.
Keywords:negative  sequence electric  energy  electric  energy metering  negative  sequence apparent  power  unbalanced  responsibility  Award  and punishment  coefficient
本文献已被 万方数据 等数据库收录!
点击此处可从《电测与仪表》浏览原始摘要信息
点击此处可从《电测与仪表》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号