首页 | 本学科首页   官方微博 | 高级检索  
     

微库仑法测汽油中氯含量的影响因素浅析
引用本文:曹薇. 微库仑法测汽油中氯含量的影响因素浅析[J]. 化工时刊, 2014, 0(7): 11-14
作者姓名:曹薇
作者单位:中国石油化工股份有限公司浙江石油分公司,浙江杭州310009
摘    要:对ZWK-2001型微机硫氯分析仪的电解池、偏压、采样电阻、气体流量、炉温、进样速度、搅拌速度等多个实验条件进行了大量实验分析和对比,同时考察了汽油中锰元素和硫元素对氯含量测定的影响,并提出了最适宜的实验条件,有利于提高微库仑法测定氯含量的准确性和精密度。

关 键 词:汽油  氯含量  微库仑滴定

Analysis on the Influence Factors on Determination of Chlorine in Gasoline with Microcoulometry Method
Cao Wei. Analysis on the Influence Factors on Determination of Chlorine in Gasoline with Microcoulometry Method[J]. Chemical Industry Times, 2014, 0(7): 11-14
Authors:Cao Wei
Affiliation:Cao Wei ( SINOPEC Zhejiang Oil Products Company, Zhejiang Hangzhou 310009)
Abstract:To improve the accuracy and precision of that method, the conditions of this method such as bias, sampling resistor,gas flow,temperature,feed rate, and stirring speed were analyzed and compared with experiment re-sults on ZWK - 2001 microcomputer sulfur and chlorine analyzer . The effects on chlorine determination of by manga-nese and sulfur that existes in Gasoline were investigated. At last, the suitable experimental conditions were concluded and presented.
Keywords:gasoline  chlorine content  microcoulometry titration