首页 | 本学科首页   官方微博 | 高级检索  
     

水轮发电机镜板产生静电引起故障的分析与处理
引用本文:陈文添.水轮发电机镜板产生静电引起故障的分析与处理[J].广东电力,2005,18(11):53-55.
作者姓名:陈文添
作者单位:广东粤电水电检修安装有限责任公司,广东,河源,517000
摘    要:因一些条件的共同存在.使某水轮发电机推力轴承的镜板带电,而且电压不断升高造成放电。在放电瞬间引起上导油盆盖与大轴间的间隙放电和推力轴承座瞬间带电.而轴承座带电又造成推力瓦测温装置烧损。鉴此,分析了镜板放电引起上导油盆盖与大轴间隙处放电及轴承座瞬间带电的原理.并阐述了故障的处理方法。

关 键 词:水轮发电机  推力轴承  镜板  静电  故障
文章编号:1007-290X(2005)11-0053-03
修稿时间:2005年4月2日

Analysis and treatment of fault caused by static electricity on hydrogenerator runner collar
CHEN Wen-tian.Analysis and treatment of fault caused by static electricity on hydrogenerator runner collar[J].Guangdong Electric Power,2005,18(11):53-55.
Authors:CHEN Wen-tian
Abstract:Under certain conditions,the thrust bearing runner of a hydrogenerator was electrified and the increasingly higher voltage led to discharge,which instantaneously caused gap discharge between the upper oil basin cover and the shaft as well as instant electrification of the thrust bearing pedestal. The electrified thrust bearing pedestal in turn resulted in the burning of the thermoscope for the thrust block.This paper analyzes the mechanism of the problem and expounds the treatment of the fault.
Keywords:hydrogenerator  thrust bearing  runner collar  static electricity  fault
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号