关于电力变压器油纸绝缘用耐受电压法代替击穿法的研究
引用本文:陈奎. 关于电力变压器油纸绝缘用耐受电压法代替击穿法的研究[J]. 变压器, 1997, 34(5): 22-27
作者姓名:陈奎
作者单位:沈阳变压器研究所
摘    要:
阐述了电力变压器油纸绝缘用耐受电压法代替击穿法的机理,并用变压器绕组油道绝缘模型的雷电冲击全波试验加以验证。

关 键 词:变压器 耐受电压 击穿试验 绝缘 油纸绝缘

Study on Testing Oil-Paper Insulation of Power Transformer by Withstand Voltage Method Instead of Breakdown Method
Chen Kui Shenyang Transformer Research Institute,Shenyang. Study on Testing Oil-Paper Insulation of Power Transformer by Withstand Voltage Method Instead of Breakdown Method[J]. Transformer, 1997, 34(5): 22-27
Authors:Chen Kui Shenyang Transformer Research Institute  Shenyang
Affiliation:Chen Kui Shenyang Transformer Research Institute,Shenyang 110025
Abstract:
The principle of testing oil-paper insulation of power transformer by withstand voltage method instead of breakdown method is introduced. And this principle is demonstrated by lightning impulse full wave test on oil-duct insulation model of transformer winding in the paper.
Keywords:Transformer   Transformer oil   Withstand voltage   Breakdown   Test   Probability  