首页 | 本学科首页   官方微博 | 高级检索  
     


Upscaling DC resistance using a Josephson junction array
Authors:Kohlmann   J. Gutmann   P. Niemeyer   J.
Affiliation:Phys.-Tech. Bundesanstalt, Braunschweig;
Abstract:
A ratio standard for DC resistance measurements in the range above about 10 kΩ using a three-terminal Josephson junction series array is described. Resistance ratios of two-terminal resistors from 1:1 to at least 1:10 are examined with a single device utilizing the voltage steps of the Josephson array as voltage sources of a potentiometer bridge configuration. Some features of the circuit are discussed. The system promises systematic ratio errors below 10-8 and uncertainties which depend only on the quality of the resistors. Preliminary measurements with a prototype instrument show a relative reproducibility of 1×10-7, limited by the noise of a commercial digital multimeter used as a detector
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏