首页 | 本学科首页   官方微博 | 高级检索  
     

托电2号炉火焰检测系统优化
引用本文:张大鹏,张俊伟. 托电2号炉火焰检测系统优化[J]. 华北电力技术, 2011, 0(2): 35-36,44
作者姓名:张大鹏  张俊伟
作者单位:内蒙古大唐国际托克托发电有限责任公司,内蒙古托克托,010206
摘    要:托电2号机组火检系统自运行以来,存在一些问题,如火检系统经常发出故障报警信号、火检探头的使用寿命较短、火检信号存在"偷看"现象等.针对以上问题,热控专业人员经过认真分析找到了原因所在,提出了行之有效的解决方法,并结合2号机组的检修对火检系统进行了优化改造.

关 键 词:火焰检测  火检探头  优化

Optimization of Flame Detection System of Tuoketuo Power Plant Unit 2
Zhang Da-peng,Zhang Jun-wei. Optimization of Flame Detection System of Tuoketuo Power Plant Unit 2[J]. North China Electric Power, 2011, 0(2): 35-36,44
Authors:Zhang Da-peng  Zhang Jun-wei
Affiliation:(Inner Mongolia Datang International Tuoketuo Power Generation Co. Ltd. ,Tuoketuo 010206, China)
Abstract:Since Tuoketuo Power Plant unit 2 was put into operation, the flame detection system has lots of problem, such as fault signals alarm occurred frequently, service life of the flame detector was shorten, and fire detectors always peep others. To solve these problems, after careful analysis the control maintenance engineers found the cause and put forward the appropriate measures. Combined with the repairing opportunity of unit 2, the flame detection system has been optimized.
Keywords:flame detection system  flame detector  optimization