首页 | 本学科首页   官方微博 | 高级检索  
     

全桥型DC/DC变换器的DMC-PID串级控制策略研究
引用本文:王利波,余明扬,王一军.全桥型DC/DC变换器的DMC-PID串级控制策略研究[J].电源学报,2018,16(6):57-62,70.
作者姓名:王利波  余明扬  王一军
作者单位:中南大学信息科学与工程学院, 长沙 410075,中南大学信息科学与工程学院, 长沙 410075,中南大学信息科学与工程学院, 长沙 410075
基金项目:国家自然科学基金资助项目(61572529)
摘    要:研究了全桥型DC/DC变换器系统的控制方法。针对现有DC/DC变换器动态响应速度慢、抗干扰能力差的现状,提出了基于状态反馈精确线性化的动态矩阵控制-比例积分微分DMC-PID(dynamic matrix control-propor-tional integral differential)串级控制方法。应用状态空间平均法建立全桥型DC/DC变换器系统的非线性模型,通过状态反馈精确线性化后得到线性化系统。为使系统获得优良的控制性能,选取DMC-PID串级控制方法。该控制方法同时具备PID算法的鲁棒性和DMC算法的快速性和稳定性,能有效地解决电源输入电压大范围波动输出电压不能及时稳定的问题。通过仿真分析和实验验证了该方案能在各种扰动工作条件下实现对变换器输出精确、快速的控制。

关 键 词:DMC-PID串级控制  状态空间平均法  状态反馈精确线性化  稳定性
收稿时间:2016/8/26 0:00:00
修稿时间:2018/4/25 0:00:00

Application of DMC-PID Cascade Control Strategy for Full-bridge DC/DC Converter
WANG Libo,YU Mingyang and WANG Yijun.Application of DMC-PID Cascade Control Strategy for Full-bridge DC/DC Converter[J].Journal of power supply,2018,16(6):57-62,70.
Authors:WANG Libo  YU Mingyang and WANG Yijun
Affiliation:School of Information Science and Engineering, Central South University, Changsha 410075, China,School of Information Science and Engineering, Central South University, Changsha 410075, China and School of Information Science and Engineering, Central South University, Changsha 410075, China
Abstract:The control method forafull-bridge DC/DC converter system is studied in this paper. In view of the present status of the existing DC/DC converter, such as a slow dynamic response speed and poor anti-interference capability, adynamic matrix control-proportional integral differential(DMC-PID) cascade control method based on state feedback linearization is proposed. The state space average method is used to establish a nonlinear model of the full-bridge DC/DC converter system. By applying state feedback linearization, a linear system is obtained. To empower the system with excellent control performance, the DMC-PID cascade control method is selected. This control method not only has the robustness of the PID algorithm, but also has the rapidity and stability of the DMC algorithm, which can effectively solve the problem that the output voltage cannot be kept stable in time when the input voltage fluctuates in a wide range.Through simulation analysis and experiments, it was proved that the proposed scheme can achieve accurate and fast control of the converter output under various disturbance conditions.
Keywords:DMC-PID cascade control  state space average method  state feedback linearization  stability
点击此处可从《电源学报》浏览原始摘要信息
点击此处可从《电源学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏