首页 | 本学科首页   官方微博 | 高级检索  
     

寒冷地区面板坝接缝止水防冻害研究
引用本文:魏祖涛,张佳,李志军. 寒冷地区面板坝接缝止水防冻害研究[J]. 西北水电, 2014, 0(6): 43-45
作者姓名:魏祖涛  张佳  李志军
作者单位:国电新疆开都河流域水电开发有限公司,新疆库尔勒841000
摘    要:寒冷地区的面板坝水位变化区的接缝止水最容易产生冰冻破坏,电站运行单位每年都要花费大量资金修复面板表面接缝止水,现采取工程措施对面板表面接缝止水加以保护,确保冬季水位变化区的接缝止水不会产生冰冻破坏,降低电站运行成本。

关 键 词:面板坝  接缝止水  冰冻破坏

Study on Frozen Protection of CFRD Joint Waterstop in Cold Region
WEI Zu-tao,ZHANG Jia,LI Zhi-jun. Study on Frozen Protection of CFRD Joint Waterstop in Cold Region[J]. Northwest Water Power, 2014, 0(6): 43-45
Authors:WEI Zu-tao  ZHANG Jia  LI Zhi-jun
Affiliation:(Guodian Kaidu River Valley Hydropower Development Co. , Ltd. , Kurle, Xinjiang 841000,China)
Abstract:In cold region, the CFRD joint waterstop in water level change range easily fails by frozen occurrence.Each year, it costs a lot to repair the frozen waterstop.Through the engineering measures to protect the surface joint waterstop, the frozen failure in winter is avoi-ded and the operation cost is reduced accordingly .
Keywords:CFRD joint waterstop frozen failure
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号