首页 | 本学科首页   官方微博 | 高级检索  
     

高温过热器异种钢接头开裂原因分析
引用本文:高义斌,董勇军,黄纯德.高温过热器异种钢接头开裂原因分析[J].山西电力,2013(6):62-64.
作者姓名:高义斌  董勇军  黄纯德
作者单位:山西电力科学研究院,山西太原030001
摘    要:针对开裂和未开裂T91+12Cr1MoVG异种钢接头进行了化学成分、力学性能、显微硬度、金相等内容的试验检查,发现开裂起源于管接头12Cr1MoVG低合金侧熔合线粗晶区,发生于再次加热过程中,属于再热裂纹,这与焊接或热处理工艺执行不到位导致焊接残余应力较大密切相关。

关 键 词:12Cr1MoVG  异种钢接头  再热裂纹  焊接工艺

Cause Analysis on the Cracking of Dissimilar Steel Welded Joints in High-temperature Superheater
GAO Yi-bin,DONG Yong-jun,HUANG Chun-de.Cause Analysis on the Cracking of Dissimilar Steel Welded Joints in High-temperature Superheater[J].Shanxi Electric Power,2013(6):62-64.
Authors:GAO Yi-bin  DONG Yong-jun  HUANG Chun-de
Affiliation:(Shanxi Electric Power Research Institute, Taiyuan, Shanxi 030001, China)
Abstract:Tests about the cracked and non-cracked T91+12Cr1MoVG dissimilar steel welded joints were carried out in terms of their chemical constituents,mechanical property,micro-hardness and metallography etc. The results showed that cracking originated from coarse-grained zone of fusion line,located at 12Cr1MoVG low-alloy side of tube joint. The cracking occurred during the reheating process,which is closely related to improper operation of welding and heat treatment.
Keywords:12Cr1MoVG  dissimilar steel welded joints  reheat cracking  welding process