首页 | 本学科首页   官方微博 | 高级检索  
     


A high-performance inverter-fed drive system of an interiorpermanent magnet synchronous machine
Authors:Bose  BK
Affiliation:Gen. Electr. Res. & Dev. Center, Schenectady, NY;
Abstract:A high-performance, fully operational four-quadrant control scheme for the interior permanent magnet (PM) synchronous machine is described. The machine operates smoothly with full performance in the constant-torque region as well as in the flux-weakening constant-power region in both directions of motion. The transition between the constant-torque region and the constant-power region is very smooth at all conditions of operation. Control in the constant-torque region is based on the vector stator flux, while constant-power region control is implemented through the feedforward vector rotator. The control system is digitally implemented using a distributed microcomputer system, and all of the essential feedback signals such as torque, flux, etc. are estimated with precision. A 70 hp drive system using a neodymium-iron-boron (NeFeB) PM machine and transistor pulse width modulation inverter was designed and extensively tested in the laboratory on a dynamometer, and performance was found to be excellent
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏