引用本文:潘大伟,闫永贵,高心心,刘峰,李相波.高强钢与典型管系材料B10和TA2之间的电偶腐蚀及其电绝缘[J].腐蚀与防护,2017,38(8).
作者姓名:潘大伟  闫永贵  高心心  刘峰  李相波
作者单位:1. 中国船舶重工集团公司第七二五研究所青岛分部,海洋腐蚀与防护重点实验室,青岛266101;2. 中国船舶重工集团公司第七二五研究所青岛分部,海洋腐蚀与防护重点实验室,青岛266101;青岛科技大学机电工程学院,青岛266061
基金项目:海洋腐蚀与防护国防科技重点实验室基金项目
摘    要:采用电偶腐蚀试验研究了某高强钢与铜镍合金(B10)和工业纯钛(TA2)在面积比为1∶1条件下的电偶腐蚀倾向以及腐蚀程度,通过改变两电偶对材料间串联绝缘电阻值,研究绝缘电阻对电偶腐蚀的影响规律。结果表明:高强钢与典型管系材料B10和TA2在海水中具有较强的电偶腐蚀倾向,偶接后高强钢作为阳极,腐蚀加剧;试验条件下,两电偶对材料间绝缘电阻高于10kΩ时,可有效控制电偶腐蚀的发生。

关 键 词:管系材料  电偶腐蚀  钛合金  铜镍合金  电绝缘

Galvanic Corrosion and Electrical Insulation between High Strength Steel and Typical Piping Materials B10 and TA2
PAN Dawei,YAN Yonggui,GAO Xinxin,LIU feng,LI Xiangbo.Galvanic Corrosion and Electrical Insulation between High Strength Steel and Typical Piping Materials B10 and TA2[J].Corrosion & Protection,2017,38(8).
Authors:PAN Dawei  YAN Yonggui  GAO Xinxin  LIU feng  LI Xiangbo
Abstract:Galvanic corrosion test was used to study the corrosion tendency and the extent of corrosion of high strength steel contacted with copper-nickel alloy (B10) or commercially pure titanium (TA2) at the area ratio of one to one.By gradually increasing the resistance between two galvanic materials,the influence rule of insulation resistance on galvanic corrosion was studied.The results show that the high-strength steel had an obvious galvanic corrosion tendency no matter it was contacted with B10 or TA2 in seawater,and the corrosion of high strength steel as an anode was aggravated after coupling.In the condition of test,galvanic corrosion rate of high strength steel decreased with the galvanic insulation resistance increasing,when the galvanic insulation resistance value between the two basic materials was higher than 10 kΩ,the extent of galvanic corrosion was controled effectively.
Keywords:piping material  galvanic corrosion  titanium alloy  copper-nickel alloy  electrically insulating