首页 | 本学科首页   官方微博 | 高级检索  
     


CO2-heat pump water heater: characteristics, system design and experimental results
Authors:Petter Neks  Hvard Rekstad  G Reza Zakeri  Per Arne Schiefloe
Affiliation:Petter Nekså, Håvard Rekstad, G. Reza Zakeri,Per Arne Schiefloe
Abstract:CO2 is one of the few non-toxic and non-flammable working fluids that do not contribute to ozone depletion or global warming, if leaked to the atmosphere. Tap water heating is one promising application for a trans-critical CO2 process. The temperature glide at heat rejection contributes to a very good temperature adaptation when heating tap water, which inherits a large temperature glide. This, together with efficient compression and good heat transfer characteristics of CO2, makes it possible to design very efficient systems. A heating-COP of 4.3 is achieved for the prototype when heating tap water from 9°C to 60°C, at an evaporation temperature of 0°C. The results lead to a seasonal performance factor of about 4 for an Oslo climate, using ambient air as heat source. Thus, the primary energy consumption can be reduced with more than 75% compared with electrical or gas fired systems. Another significant advantage of this system, compared with conventional heat pump water heaters, is that hot water with temperatures up to 90°C can be produced without operational difficulties.
Keywords:refrigerant  CO2  trans-critical  heat pump  COPfrigorigè  ne  CO2  cycle transcritique  pompe à  chaleur  COP
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏