首页 | 本学科首页   官方微博 | 高级检索  
     

钢管混凝土柱-双面组合作用梁框架节点抗震性能试验研究
引用本文:李杨,李延涛,邢万里,丁井臻,宗金辉.钢管混凝土柱-双面组合作用梁框架节点抗震性能试验研究[J].工程力学,2020,37(7):99-109.
作者姓名:李杨  李延涛  邢万里  丁井臻  宗金辉
作者单位:1.河北工业大学土木与交通学院,天津 300401
基金项目:国家重点研发计划“绿色建筑及建筑工业化”重点专项项目(2017YFC0703401);河北省教育厅在读研究生创新能力培养资助项目
摘    要:为了研究钢-混凝土双面组合作用梁框架节点的抗震性能,设计了3个钢-混凝土双面组合作用梁十字形框架节点和1个普通钢-混凝土单面组合作用梁十字形框架节点,并对其进行低周往复加载试验,对比分析其破坏模式、极限承载力、初始刚度、耗能能力、延性、刚度退化等抗震性能指标;通过改变下部混凝土板厚度和传力方式,研究下部混凝土板不同厚度和不同传力方式对双面组合作用梁力学性能的影响。结果表明:与普通钢-混凝土单面组合作用梁框架节点相比,钢-混凝土双面组合作用梁十字形框架节点具有更高的承载力和刚度,适用于荷载较大的结构,但在延性、刚度退化和耗能能力等方面无明显优势;下部混凝土板采用集中传力和均匀传力的方式对双面组合作用梁抗震性能的影响无明显区别;下部混凝土板采用预制法制作和螺栓连接更加方便、可靠。

关 键 词:双面组合作用梁十字形框架节点    低周往复试验    抗震    刚度    承载力
收稿时间:2019-08-01

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF FRAME JOINTS WITH CONCRETE-FILLED STEEL TUBULAR COLUMN AND DOUBLE-SIDED COMPOSITE BEAM
Affiliation:1.School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin 300401, China2.China Institute of Building Standard Design & Research, Beijing 100048, China
Abstract:In order to study the seismic performance of frame joints with concrete-filled steel tubular column and double-sided composite beam, three cross-shaped frame joints of a double composite steel-concrete beam and one cross-shaped frame joint of a normal single composite steel-concrete beam were designed, and low-cycle reciprocating loading tests were carried out to compare and analyze their failure modes and ultimate bearing capacity, initial stiffness, energy dissipation capacity, ductility, stiffness degradation, and other seismic performance indicators. By changing the thickness and load transfer mode of the bottom concrete slab, the influence of different thickness and different load transfer mode of the bottom concrete slab on the mechanical properties of the double-sided composite beam is studied. The results show that: compared with normal single composite steel-concrete beam-frame joints, double composite steel-concrete beam-frame joints have higher bearing capacity and stiffness, and are suitable for structures with larger loads, but have no obvious advantages in ductility, stiffness degradation and energy dissipation capacity. There is no obvious difference in the effect of concentrated and uniform load transfer on the seismic performance of double composite beams, and prefabricated concrete slabs and bolted connections are more convenient and reliable.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《工程力学》浏览原始摘要信息
点击此处可从《工程力学》下载全文