摘    要:针对一起变电站并联电容器爆炸事故进行分析,结合并联电容器的保护配置、控制闭锁回路等情况,找出引发该事故的直接原因和间接原因,并针对此情况实施改进措施,调整至今未发生类似事故,验证了分析的正确性。

关 键 词:并联电容器装置  保护配置  控制回路  闭锁回路

Analysis and Improvements of an Explosion Accidents of Shunt Capacitors
SONG Jia , YANG Yong-shan , JIANG Qi , LI Ling.Analysis and Improvements of an Explosion Accidents of Shunt Capacitors[J].Power Capacitor $ Reactive Power Compensation,2012,33(2):73-76.
Authors:SONG Jia  YANG Yong-shan  JIANG Qi  LI Ling
Affiliation:(Shandong Qingdao Power Supply Company,Qingdao 266000,China)
Abstract:Combined with the protection configuration of shunt capacitors,the control blocking circuit etc.,this paper introduces the direct and indirect reasons for an explosion accident of shunt capacitors.The improvement measure had been performed,up to now similar incidents not yet recurred,so the suggestions correctness have been verified.