首页 | 本学科首页   官方微博 | 高级检索  
     

剪力墙抗震能力设计措施有效性的校验与改进
引用本文:韩军,李英民,陈伟贤.剪力墙抗震能力设计措施有效性的校验与改进[J].土木与环境工程学报,2011,33(4):42-51.
作者姓名:韩军  李英民  陈伟贤
作者单位:1. 重庆大学,土木工程学院;山地城镇建设与新技术教育部重点实验室,重庆400045
2. 中山大学基建处,广州,510275
基金项目:中央高校基本科研业务费,教育部博士点基金
摘    要:为研究有效的剪力墙抗震能力设计措施,引导其在强震中实现可控的预期破坏模式,通过理论分析指出目前剪力墙能力设计措施存在的问题,通过精细有限元动力时程算例分析,校验了中国规范剪力墙能力调整措施的有效性;提出了改进措施,并进行了算例验证。结果表明,在刚性地基假定下中国2001版抗震规范抗弯能力调整措施使得剪力墙底截面在大震下弯曲延性需求过大、竖向承载力丧失,而底部延性加强区其他部位不易屈服,现行规范采用的抗剪能力措施不能有效避免底部加强区以上楼层剪力墙剪切失效;提出的抗弯和抗剪能力设计措施经算例验证是有效的。

关 键 词:破坏模式  能力设计  框架-剪力墙结构  动力分析
收稿时间:2011/2/20 0:00:00

Verification and Improvement of the Effectiveness of Seismic Capacity Design Measures of Shear Wall
HAN Jun,LI Ying-min and CHEN Wei-xian.Verification and Improvement of the Effectiveness of Seismic Capacity Design Measures of Shear Wall[J].Journal of Civil and Environmental Engineering,2011,33(4):42-51.
Authors:HAN Jun  LI Ying-min and CHEN Wei-xian
Affiliation:HAN Jun , LI Ying-min (la. College of Civil Engineering; lb. Key I.aboratory of New Technology for Construction of Cities in Mountain Area, Ministry of Education, Chongqing University, Chongqing 400045, P. R. China 2 Infrastructure Department, Sun Yat Sen University, Guangzhou 510275, P. R. China)
Abstract:In order to investigate the effective seismic capacity design measures of shear wall and to realize expected failure modes under strong earthquake, the existing problems in current seismic capacity design measures are pointed out through theoretical analysis. The effectiveness of the measures of Chinese seismic design code is verified by fine finite element dynamic time-history analysis of examples. Improving measures are then put forward and are verified through example analysis. It is shown the bending ductile demand of bottom section of shear wall increases too much based on moment capacity design measures of Chinese seismic design code 2001 in the rigid foundation assumption under rare earthquake action, and its bearing capacity for vertical axis force loses; the shear capacity design measures of current seismic design code would lead to shear failure in the stores above the bottom ductility strengthening area. Some improved bending and shear seismic capacity design measures of shear wall are proposed and are verified to be effective.
Keywords:failure modes  seismic capacity design  frame shear wall structure  dynamic analysis