首页 | 本学科首页   官方微博 | 高级检索  
     

变压器短路损坏原因分析及对策
引用本文:黎大健,赵坚.变压器短路损坏原因分析及对策[J].广西电力,2013(5):34-36.
作者姓名:黎大健  赵坚
作者单位:广西电网公司电力科学研究院,南宁530023
摘    要:为了提高变压器的运行可靠性,对2005年以来多起变压器短路损坏事故进行分析.分析结果表明,主变压器抗短路能力不强、历次短路冲击的累积效应以及变压器出口设备故障是造成事故频发的主要原因.根据分析结果提出了防止同类故障的管理措施和技术措施.

关 键 词:变压器损坏  短路故障  技术措施

Analysis and Countermeasures on Transformer Short-Circuit Damage
LI Da-jian,ZHAO Jian.Analysis and Countermeasures on Transformer Short-Circuit Damage[J].Guangxi Electric Power,2013(5):34-36.
Authors:LI Da-jian  ZHAO Jian
Affiliation:(Guangxi Power Grid Electric Power Research Institute, Nanning 530023, China)
Abstract:In order to improve the operation reliability of transformer,accidents of transformer short-circuit damage since 2005 are analyzed. The results show that the lower capability of anti-short circuit of main transform,the cumulative effect of multi short-circuit impacts and the equipment fault at outlet of the transformer are main reasons of frequent accidents. Management and technical measures are proposed to prevent the same type fault.
Keywords:transformer damage  short-circuit fault  technical measure
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号