Measurement of fracture initiation toughness and crack resistance in instrumented Charpy impact testing |
| |
Authors: | J.P Tronskar M.A MannanM.O Lai |
| |
Affiliation: | a DNV Technology Centre, Det Norske Veritas Pte. Ltd., 10 Science Park Drive, Singapore 118224, Singapore b National University of Singapore, Singapore 118224, Singapore |
| |
Abstract: | ![]() A new method has been developed involving direct measurement of the load-line displacement during instrumented Charpy testing. The method uses a laser interferometer to measure displacement in addition to the load-line displacement derived from the load signal. Tests were conducted using fatigue precracked and V-notched test pieces in the temperature range +23°C to −80°C on a conventional ship grade steel, a pressure vessel steel and two welded joints. Good correlation was found between the J0.2 initiation fracture toughness determined by the multi-specimen method and the Ji fracture toughness determined from single specimens using the new method to detect ductile fracture initiation. |
| |
Keywords: | Steel Instrumented impact testing Displacement measurement Dynamic crack resistance Dynamic initiation fracture toughness |
本文献已被 ScienceDirect 等数据库收录! |