摘    要:以某钢铁企业自备火力发电机组为例,分析了其引风系统的现状及存在问题,结合系统实测数据、风机串并联及变频调速的原理,提出了节能改造方案,并指出容易产生的不良改造方案及其危害性,初步预测了节能改造方案的效果,得出了引风系统改造的一些基本看法。

关 键 词:机组  引风系统  节能  改造
文章编号:1004-7948(2008)03-0030-03
收稿时间:2007-12-11
修稿时间:2008-02-19

The discussion of the energy-saving rebuilding method for the induced draft system of a power plant in the Steel Enterprises
NI Jian-dong,XU Jian.The discussion of the energy-saving rebuilding method for the induced draft system of a power plant in the Steel Enterprises[J].Energy Conservation,2008,27(3):30-32.
Authors:NI Jian-dong  XU Jian
Abstract:By example of a powerplant for the steel enterprises,analyzing the present situation and problems of its induced draft system,with the testing date and the theory of parallel running fan,puting forward the good energy-saving method and the bad one,indicating the endanger of the bad method.forecasting the energy-saving effect,concluding some opinions in this paper.