首页 | 本学科首页   官方微博 | 高级检索  
     

精馏塔的压降测量研究(英文)
作者姓名:T.J. Cai  M.R. Resetarits
作者单位:Fractionation Research, Inc., 424 S. Squires St, Suite 200, Stillwater, OK 74074, USA
摘    要:Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sec-tional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is con-firmed by a fundamental fluid dynamics analysis.

关 键 词:蒸馏塔  压降  测量  压力蒸汽  动力学分析  水汽凝结  实验数据  压力下降
收稿时间:2011-6-10
修稿时间:2011-6-10  

Pressure drop measurements on distillation columns
T.J. Cai,M.R. Resetarits.Pressure drop measurements on distillation columns[J].Chinese Journal of Chemical Engineering,2011,19(5):779-783.
Authors:TJ Cai  MR Resetarits
Affiliation:Fractionation Research, Inc., 424 S. Squires St, Suite 200, Stillwater, OK 74074, USA
Abstract:Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis.
Keywords:distillation  tray  packing  pressure drop  hydraulics
本文献已被 CNKI ScienceDirect 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号