艇用除湿机通信与监控系统设计 |
| |
引用本文: | 李建民,秦洪艳,韩训梅,姜金花,徐伟,王海巧. 艇用除湿机通信与监控系统设计[J]. 工业控制计算机, 2010, 23(7): 46-47 |
| |
作者姓名: | 李建民 秦洪艳 韩训梅 姜金花 徐伟 王海巧 |
| |
作者单位: | 三江学院,江苏,南京,210012;三江学院,江苏,南京,210012;三江学院,江苏,南京,210012;三江学院,江苏,南京,210012;三江学院,江苏,南京,210012;三江学院,江苏,南京,210012 |
| |
摘 要: | ![]() 从除湿机网络监控系统的总体方案入手,介绍了通信网络、通信程序和监控的组态与设计过程。根据应用的需要,将通信网络分为了艇内总线和艇间总线两个层次,选择了IEC61158中的PROFIBUS作为现场层的艇内总线,选择IEC61158中的PROFINET作为艇间总线,并采用WinCC作为上位机的监控组态软件。整个系统层次清晰,结构合理,符合艇用除湿机的监控要求。经试验和测试,该系统可以很好的完成多空间多节点除湿机的远程监控,具有很大的应用价值。
|
关 键 词: | 除湿机 PROFIBUS 工业以太网 WinCC |
Design of Dehumidifiers with Communication and Supervisory Systems |
| |
Abstract: | ![]() Design of dehumidifiers with communication and supervisory systems is presented in this paper,including communicatin networks,programs and Configarations.Communication networks are divided into two kinds:in-vessel networks and amongvessel networks.PROFIBUS of IEC61158 is choosed as in-vessel networks,and PROFINET of IEC61158 as among-vessel networks.WinCC is selected as supervisory configaration tool.The system with a clear structrure,is well conformed to the application of dehumidifiers.The experiment of the supervisory system are shown,which confirmed that the system was better in dehumidifiers with multi-spaces and multi-stations. |
| |
Keywords: | PROFIBUS WinCC |