Abstract:In order to solve strip reciprocating and quick- moving running deviation at the exit of heat section for vertical continuous annealing furnace, the thermal crown of furnace roller was analyzed quantitatively and regression method was used to determine the impact of roller crown on strip running deviation. And then the alarm program for strip running deviation was established, which can give early warning of strip running deviation and adjust the model parameter and the heating and cooling temperature rate simultaneously. With the application of this system on a continuous annealing machine for cold rolling in Shougang Jingtang Company, the strip running deviation which caused by thermal crown of furnace roller can be solved.
Keywords:vertical continuous annealing furnace  radiant tube furnace (RTF) section  The thermal crown  Heating model  heating and cooling rate  strip deviation  