首页 | 本学科首页   官方微博 | 高级检索  
     

海水-干原油换热器故障分析和改进措施
引用本文:赵军凯,彭湘桂,刘瑜珩,吕立功,朱宪,亓俊良. 海水-干原油换热器故障分析和改进措施[J]. 石油化工设备, 2007, 36(Z1): 85-86
作者姓名:赵军凯  彭湘桂  刘瑜珩  吕立功  朱宪  亓俊良
作者单位:中海油基地集团,采油服务公司,天津,300452
摘    要:
对渤海曹妃甸油田海水-干原油换热器运行2 a来出现的几次故障进行了分析,并由此进行了相应改造,实施效果良好,可供今后类似换热器的安装、调试、操作与维修参考。

关 键 词:管壳式换热器  海水腐蚀  泥沙  原因分析  改进措施
文章编号:1000-7466(2007)增刊-0085-02
修稿时间:2006-06-06

Failure Analysis and Improving Measures for Sea Water/dry Crude Heat Exchanger of CFD Oilfield in Bohai Bay
ZHAO Jun-kai,PENG Xiang-gui,LIU Yu-heng,LU Li-gong,ZHU Xian,QI Jun-liang. Failure Analysis and Improving Measures for Sea Water/dry Crude Heat Exchanger of CFD Oilfield in Bohai Bay[J]. Petro-Chemical Equipment, 2007, 36(Z1): 85-86
Authors:ZHAO Jun-kai  PENG Xiang-gui  LIU Yu-heng  LU Li-gong  ZHU Xian  QI Jun-liang
Abstract:
This paper analyses sea water/dry crude heat exchanger failure of CFD Oilfield in Bohai Bay,points out seal life plugging and shell fragments/mud/sand fraction of tube bundle is main cause of the equipment failure.Based on the analysis,remedial modification for the exchanger was completed.It is a reference for similar exchanger installation,commissioning,operation and maintenance.
Keywords:tube and shell heat exchanger  sea water corrosion  mud and sand  failure analysis  improvement
本文献已被 CNKI 万方数据 等数据库收录!