首页 | 本学科首页   官方微博 | 高级检索  
     

搬运机真空吸头不报警故障的分析及解决方法
引用本文:齐峻岭. 搬运机真空吸头不报警故障的分析及解决方法[J]. 真空, 2001, 0(5): 44-45
作者姓名:齐峻岭
作者单位:广东深圳赛格三星股份有限公司
摘    要:叙述了在自动化生产线上,搬运机设备的真空吸头在没有吸起被搬运的物体时,真空开关不报警,导致被搬运物体损坏,甚至引发不安全的故障现象。对此故障进行了分析,并提提出了相应的解决方法。

关 键 词:真空吸头 压力损失 报警 故障 维修 搬运机 原因分析
文章编号:1002-0322(2001)05-0044-02
修稿时间:2001-09-24

Analysis and solution on the fault that automatic transfer machine''''s vacuum chuck can''''t give an alarm
QI Jun-ling. Analysis and solution on the fault that automatic transfer machine''''s vacuum chuck can''''t give an alarm[J]. Vacuum(China), 2001, 0(5): 44-45
Authors:QI Jun-ling
Abstract:The article introduces the fault of a transfer machine's vacuum chuck on an automatic production line. When the vacuum chuck doesn't suck the object well, vacuum switch doesn't give an alarm to control system, as a result, the object will be damaged, even it may cause an accident. Here an analysis of the fault is given, and the proper solutions are offered.
Keywords:vacuum chuck  pressure loss  alarm  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号