首页 | 本学科首页   官方微博 | 高级检索  
     

2号锅炉带不滿负荷问题的诊断及燃烧优化调整
引用本文:苗宗清.2号锅炉带不滿负荷问题的诊断及燃烧优化调整[J].华北电力技术,2014(7):62-66.
作者姓名:苗宗清
作者单位:大唐内蒙古多伦煤化工有限责任公司,内蒙古多伦027300
摘    要:对2号锅炉改造后依然达不到额定出力的问题进行了分析,确定锅炉制粉系统的运行参数不能适应煤种水分增加是影响机组出力的主要原因。锅炉进行燃烧优化调整后,磨煤机出力由原20 t/h提高到30 t/h,机组出力从原295 t/h提高到410 t/h,锅炉效率达到92%,使锅炉出力不足的问题得到了彻底的解决。

关 键 词:电站锅炉  燃烧优化  磨煤机  诊断

Diagnosis of Non-rated Output of Boiler No.2 and Combustion Optimization Adjustment
Miao Zongqing.Diagnosis of Non-rated Output of Boiler No.2 and Combustion Optimization Adjustment[J].North China Electric Power,2014(7):62-66.
Authors:Miao Zongqing
Affiliation:Miao Zongqing (Inner Mongolia Datang Duolun Coal Chemical Co. Ltd.,Duolun 027300,China)
Abstract:The problem that the output of the boiler No. 2 could not reach to the rated output after transformation was analyzed,it is determined that the operating parameters of boiler pulverizing system unmatching to increasing coal moisture was the main factor affected the output capacity of unit. After boiler combustion optimization adjustment, mill capacity increased from original 20 t/h to 30 t/h, the unit output increased from original 295 t/h to 410 t/h, boiler efficiency could reach 92% ,the problem of non-rated output of boiler had been solved completely.
Keywords:power plant boiler  combustion optimization  coal mill  diagnosis