首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal-hydraulic and stress analysis of AP1000 reactor containment during LOCA in dry cooling mode
Authors:ShSheykhi  STalebi  MSoroush  EMasoumi
Affiliation:1. Department of Energy Engineering and Physics, Amirkabir University of Technology(Tehran Polytechnic), 424 Hafez Avenue, P.O.Box 15875-4413, Tehran, Iran;2. Young Researchers and Elite Club, Islamic Azad University,South Tehran Branch, Tehran, Iran
Abstract:Some kinds of break in the reactor coolant system may cause the coolant to exit rapidly from the failure site,which leads to the loss of coolant accident (LOCA).In this paper,a stress analysis of an AP1000 reactor containment is performed in an LOCA,with the passive containment cooling system (PCCS) being available and not available for cooling the wall's containment.The variations in the mechanical properties of the wall's containment,including elastic modulus,strength,and stress,are analyzed using the ABAQUS code.A general two-phase model is applied for modeling thermal-hydraulic behavior inside the containment.Obtained pressure and temperature from thermal-hydraulic models are considered as boundary conditions of the ABAQUS code to obtain distributions of temperature and stress across steel shell of the containment in the accident.The results indicate that if the PCCS fails,the peak pressure inside the containment exceeds the design value.However,the stress would still be lower than the yield stress value,and no risk would threaten the integrity of the containment.
Keywords:Two-phase flow  LOCA  Containment integrity  AP1000 reactor
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏