首页 | 本学科首页   官方微博 | 高级检索  
     


Establishment of a calibration curve for an isocentric cobalt unit using Monte Carlo simulation
Authors:Seyed Milad Vahabi  Mojtaba Shamsaie-Zafarghandi
Affiliation:Department of Energy Engineering and Physics, Amirkabir University of Technology, 424 Hafez Ave,P.O.Box 15875-4413, Tehran, Iran
Abstract:Measurement of dose distribution in patients during radiotherapy is impossible.The Monte Carlo simulation is an alternative method for dose calculations.In routine radiotherapy,the source-to-surface distance (SSD) method is not practical for an isocentric unit because it requires numerous values of tissue-air ratios and inverse square law.Therefore,this method is time consuming.In this paper,the curves of relative depth doses were obtained for three different SSDs using the MCNP4C Monte Carlo simulation and approximated with a single curve called calibration curve.This curve was compared to the curve obtained by published data,differing in approximately 5% in the worst case.It was also observed that the obtained results were more accurate for distances between-5 and 10 cm from source-to-axis distance.
Keywords:Radiotherapy  Source-to-surface distance (SSD)  Source-to-axis distance (SAD)  Calibration curve  Isocentric unit  Depth dose
本文献已被 CNKI 万方数据 等数据库收录!