We measured lung compliance, pulmonary flow-resistance, and expiratory reserve volume (ERV) in ten healthy young adults in sitting, supine, and lateral positions. Average lung compliance was 0.21 in sitting, 0.19 in lateral and 0.16 L.cm H2O-1 in supine positions. The change was significant (p less than 0.01) between sitting and supine position. Flow-resistance increased from 1.78 in sitting to 2.5 cm H2O.L-1.s (p less than 0.001) in lateral positions, and did not increase further in the supine posture in spite of a 35 percent decrease in ERV (p less than 0.001). Since it is known that lower airways resistance increases with decreasing lung volume, the lack of change in flow-resistance when shifting from lateral to supine posture suggests that upper airways flow-resistance (larynx and oropharynx) is greater in the lateral decubitus than in the supine positions. The decrease of lung compliance in horizontal postures probably reflects increased pulmonary blood volume and small airways closure.