首页 | 本学科首页   官方微博 | 高级检索  
     

电絮凝法应用于洗煤废水处理的研究
引用本文:檀朝阳,季献华,吴军.电絮凝法应用于洗煤废水处理的研究[J].工业水处理,2017,37(7).
作者姓名:檀朝阳  季献华  吴军
作者单位:1. 扬州大学环境科学与工程学院,江苏扬州,225127;2. 江苏京源环保股份有限公司,江苏南通,226000
摘    要:研究了电絮凝法用于洗煤废水处理。在连续流的运行条件下,研究考察了水力停留时间、极板间距和数量、电流以及进水浓度等因素对电絮凝处理废水效果影响。实验结果表明:水力停留时间15 min、极板间距1 cm和极板数量24块、电流为15 A以及pH=7.5条件下,能够有较好的处理效果,进水悬浮固体(SS)为300 mg/L时,SS去除率达85%以上,出水SS为40 mg/L、浊度为2.2 NTU。

关 键 词:连续流  电絮凝  洗煤废水

Research on the application of electro-coagulation method to the treatment of coal washing wastewater
Tan Chaoyang,Ji Xianhua,Wu Jun.Research on the application of electro-coagulation method to the treatment of coal washing wastewater[J].Industrial Water Treatment,2017,37(7).
Authors:Tan Chaoyang  Ji Xianhua  Wu Jun
Abstract:Electro-coagulation method has been proposed to be applied to the treatment of coal washing wastewater in form of continuous flow,and the influences of the factors,such as different HRT,distance between the electrode plates,and the number of electrode plates,current,influent concentration,etc. on the wastewater treatment have been studied and investigated. The experimental results show that when the parameter conditions are as follows:HRT is 15 min,distance between plates 1 cm,the number of plates 24,current 15 A,pH=7.5,better treatment effects can be obtained . When the influent initial suspended solids(SS)about 300 mg/L,the SS removing rate reaches 85%above,the effluent SS is 40 mg/L,turbidity 2.2 NTU.
Keywords:continuous flow  electro-flocculation  coal washing wastewater
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号