首页 | 本学科首页   官方微博 | 高级检索  
     


Preventing expulsive hemorrhage using an anterior chamber maintainer to eliminate hypotony
Authors:M Blumenthal  A Grinbaum  EI Assia
Affiliation:Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel.
Abstract:
We describe a method in which constant infusion inflow through an anterior chamber maintainer (ACM) is used to maintain positive intraocular pressure (IOP) during cataract extraction through a self-sealing tunnel incision. A retrospective review of patient records showed that the difference in the incidence of intraoperative suprachoroidal hemorrhage was significantly greater in eyes in which IOP was not constant throughout surgery than in eyes in which IOP was maintained using the ACM system.
Keywords:
本文献已被 PubMed 等数据库收录!