Experimental research on the seismic behavior of CSPSWs connected to frame beams |
| |
Authors: | Guo Lanhui Ma Xinbo Li Ran Zhang Sumei |
| |
Affiliation: | School of Civil Engineering, Harbin Institute of Technology, Harbin 50090, China |
| |
Abstract: | The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible outof-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at comers were shown to be an effective way to increase the energy dissipation capacity of CSPSWs. |
| |
Keywords: | steel plate shear wall (SPSW) composite steel plate shear wall (CSPSW) seismic behavior ductility |
本文献已被 万方数据 等数据库收录! |
|