Measurement of the coolant flow rate using correlation of temperature fluctuations
Authors:G Por  M Berta  M Csuvar
Affiliation:

aBudapest University of Technology and Economics, H-1525, Budapest, Hungary

Abstract:The transit time of the coolant, and thus its velocity, has been measured using the temperature fluctuation at the outlet of a reactor core. An impulse response function estimation is introduced, which substitutes the widely used cross-correlation measurement technique. It is shown in theory and practice that the time delay estimation is improved when using the impulse response function instead of the cross-correlation function in parameter estimation. Extremely low velocities (down to 2 cm/sec) have been measured in a natural circulation regime in a research reactor.
Keywords:transfer function  impulse response  cross correlation function  fluctuation measurements  coolant velocity estimation