Thermodynamic analysis of a new renewable energy based hybrid system for hydrogen liquefaction |
| |
Authors: | T.A.H. Ratlamwala I. Dincer M.A. Gadalla M. Kanoglu |
| |
Affiliation: | 1. Faculty of Engineering and Applied Science, University of Ontario Institute of Technology, 2000 Simcoe Street North, Oshawa, Ontario L1H 7K4, Canada;2. Department of Mechanical Engineering, American University of Sharjah, Sharjah, U.A.E |
| |
Abstract: | In this paper, a parametric study of the triple effect absorption cooling system (TEACS) integrated with solar photo-voltaic/thermal (PV/T), geothermal, and Linde–Hampson cycle is conducted. The effect of different operating parameters on the COPs, ratio ‘n’, amount of hydrogen gas pre-cooled, amount of hydrogen liquefied, and utilization factor of the integrated system are studied. It is found that when mass flow rate of air increases the energetic and exergetic COPs decrease in an exponential form from 2.6 to 1.9, and 0.4 to 0.3, respectively. The amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.39 kg/s to 0.32 kg/s and 0.082 kg/s and 0.066 kg/s, respectively with increase in mass flow rate of air. Moreover, the amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.42 to 0.27, and 0.088 to 0.066, respectively with increase in mass flow rate of geothermal. In addition, energetic and exergetic utilization factors of integrated system decrease from 0.059 to 0.037, and 0.21 and 0.13, respectively with increase in mass flow rate of geothermal. |
| |
Keywords: | Solar PV/T Geothermal Linde&ndash Hampson cycle Liquefaction Hydrogen Exergy |
本文献已被 ScienceDirect 等数据库收录! |
|