首页 | 本学科首页   官方微博 | 高级检索  
     

六相同步发电机的稳态电磁参数
引用本文:苟智德,孙玉田,张春莉,魏玉国,贲喜鹏. 六相同步发电机的稳态电磁参数[J]. 电机与控制应用, 2021, 48(3): 62-67
作者姓名:苟智德  孙玉田  张春莉  魏玉国  贲喜鹏
作者单位:哈尔滨电机厂有限责任公司,黑龙江 哈尔滨 150040
摘    要:
从Park方程的基本原理出发,建立了六相同步发电机的基本方程,得到了六相同步发电机的d轴等值电路和q轴等值电路。等值电路中的综合互感抗体现了六相同步发电机2个Y之间的磁耦作用,由电枢反应电抗和综合漏互感抗2部分组成。通过对六相同步发电机单Y运行(另一Y开路)和双Y运行的分析,得出双Y运行同步电抗为2倍的单Y运行同步电抗与单Y自漏抗之差。以空载短路试验的实例,测试了六相同步发电机特性曲线,以及d轴同步电抗、自漏抗和短路比。从电磁理论分析和实际运行特性2方面,验证了六相同步发电机的稳态电磁参数。

关 键 词:六相同步发电机  双Y移30°  综合互感抗  自漏抗  磁耦作用
收稿时间:2020-10-29
修稿时间:2021-01-08

Steady-State Electromagnetic Parameters of 6-Phase Synchronous Generator
GOU Zhide,SUN Yutian,ZHANG Chunli,WEI Yuguo,BEN Xipeng. Steady-State Electromagnetic Parameters of 6-Phase Synchronous Generator[J]. Electric Machines & Control Application, 2021, 48(3): 62-67
Authors:GOU Zhide  SUN Yutian  ZHANG Chunli  WEI Yuguo  BEN Xipeng
Affiliation:Harbin Electric Machinery Company Limited, Harbin 150040, China
Abstract:
Based on the basic principle of Park equation, the basic equation of the 6-phase synchronous generator is established, and d-axis and q-axis equivalent circuits of 6-phase synchronous generator are obtained. Comprehensive mutual reactance in equivalent circuits reflects the magnetic coupling function between double Y of the 6-phase synchronous generator. It consists of armature reaction reactance and comprehensive mutual leakage reactance. Through the analysis of single Y operation (the other Y no-load ) and double Y operation of the 6-phase synchronous generator, it can be obtained that double Y synchronous reactance is equal to the difference of 2 times single Y synchronous reactance and self leakage reactance. Taking the example of no-load short-circuit test, the characteristic curve of 6-phase synchronous generator, the d-axis synchronous reactance, the self leakage reactance, and the short-circuit ratio are measured. The steady-state electromagnetic parameters of the 6-phase synchronous generator are verified with the electromagnetic theory analysis and practical operation characteristics.
Keywords:6-phase synchronous generator  double Y with 30°phase-displacement  comprehensive mutual reactance  self leakage reactance  magnetic coupling function
本文献已被 维普 等数据库收录!